UO-ED 50 - 1,200 Z CD Counterpressure RO units with duplex softener

Producer

The ready-to-connect combi unit includes a pre-filter, a backflow preventer, a duplex water softener, a limitron hardness control device and a counterpressure reverse osmosis unit. It is used for the desalination of water with a salinity of up to 1,000 mg/l . It is designed for a permeate counterpressure of 4 bars and can be operated with up to 7 bars. The unit is equipped with a compact rotary vane pump (unit size 50 and 150) or a high-quality centrifugal pump (unit size 300 - 1,200) as well as a full-flow diaphragm pressure vessel. The microprocessor controller RO digital enables fully automatic operation with logging of all relevant operating data and freely adjustable limit values.

Benefits

  • Ready-to-connect unit including pre-treatment
  • Simple installation on site with only four connection points (drinking water, permeate, waste water, socket)
  • Design with minimal dead zones and hygienic operation to meet the requirements of air conditioning applications
  • Transport of permeate over several floors possible, no permeate storage required
  • Versatile RO digital controller with logging of operation data and many parametrisation options

Applications

  • Continuous water softening and desalination
  • For the direct supply of e.g. air-conditioning systems such as humidifiers with water according to VDI 6022

Controller :
RO digital
Desalination rate min.:
97 %
Permeate recovery:
75 – 80 %
Permeate back pressure max.:
4 - 7 bar
pH value operation:
6.5 – 9.5
pH value cleaning:
2 – 12
Ambient temperature:
5 – 40 °C
Conditions of use:
The unit may only be used for the desalination of feed water with drinking water quality or appropriately pre-treated well or surface water. The unit is designed for a salinity (TDS) of 1,000 mg/l and a temperature of 15 °C. Under these conditions, the projected permeate output is achieved even after three years of operation. The permeate yield depends on the raw water quality and the pre-treatment. The following parameters must be maintained in the feed water:
Free chlorine:
not detectable
Iron (Fe):
< 0.2 mg/l
Manganese (Mn):
< 0.05 mg/l
Silica (SiO2):
< 25 mg/l
Silt density index (SDI):
< 3
Feed water temperature:
5 – 35 °C
Feed water pressure:
4 – 6 bar
Pressure fluctuation:
± 0.5 bar
 
 
Enquire for more information
please weait… Your data is being loaded...

Article no. Product name /
Permeate l/h (at 4 bars)
Mains connection
kW / V / Hz
Hydraulic connection
feed / permeate / conc.
Dimensions in mm
W x D x H
00420250 UO-ED 50 Z CD
Single article
UO-ED 50 Z CD 0.25 / 230 / 50 DN 20 / DN 15 / DN 15 1,700 x 800 x 1,560
00420251 UO-ED 150 Z CD
Single article
UO-ED 150 Z CD 0.55 / 230 / 50 DN 20 / DN 15 / DN 15 1,700 x 800 x 1,560
00420252 UO-ED 300 Z CD
Single article
UO-ED 300 Z CD 1.50 / 3 x 400 / 50 DN 20 / DN 15 / DN 15 1,810 x 800 x 1,680
00420253 UO-ED 600 Z CD
Single article
UO-ED 600 Z CD 1.50 / 3 x 400 / 50 DN 20 / DN 15 / DN 15 1,900 x 800 x 1,750
00420254 UO-ED 900 Z CD
Single article
UO-ED 900 Z CD 2.20 / 3 x 400 / 50 DN 20 / DN 15 / DN 15 1,900 x 800 x 1,750
00420255 UO-ED 1200 Z CD
Single article
UO-ED 1200 Z CD 2.20 / 3 x 400 / 50 DN 20 / DN 15 / DN 15 2,040 x 800 x 2,000